ž籤 è¹öÀåºñÀÇ ¼±µÎÁÖÀÚ!
°í°´´Ô²² ÃÖÀûÀÇ ¼Ö·ç¼ÇÀ» Á¦°øÇÕ´Ï´Ù.

CHAMBERS > Reliability Chambers

Reliability Chambers

Reliability Chamber - TH Chamber  Custom Made


Specification NEC 110 NEC Walk IN
Exposure Dimension (WxDxH in m) 1.0x1.0x1.0 User »ç¾çÇùÀÇ
Exposure Vol(in Liter) 1000L User »ç¾çÇùÀÇ
Temperature Operating Range -50¡É~+150¡É(W/O Radiation) -50¡É~+150¡É(W/O Radiation)
Ramp Rate (During Heating) 2.0¡É/min(´Ü -40¡É±îÁö Àû¿ë) 1.7¡É/min(´Ü -40¡É±îÁö Àû¿ë)
Ramp Rate (During Cooling) 2.0¡É/min(´Ü -40¡É±îÁö Àû¿ë) 1.7¡É/min(´Ü -40¡É±îÁö Àû¿ë)
Temperature Accuracy ¡¾1¡É ¡¾1¡É
Humidity Range and Accuracy 30~95% RH 30~95% RH
Cooling Mechanism Air-cooled or Waer-cooled Air-cooled or Waer-cooled
Door, Inner Chamber Material Single type door, SUS 304 Double wing or single type door, SUS 304
Electric other voltage upon request 380V¡¾10%(3,N,PE)AC,50/60Hz 380V¡¾10%(3,N,PE)AC,50/60Hz
Physical Dimension(WxDxH in m) 1.53mx1.55mx2.15m User »ç¾çÇùÀÇ




Ç׿ÂÇ×½À±â´Â ¼ÒÇüºÎÇ°, ´ëÇüºÎÇ°, ¹Ý¼ºÇ°, ¿Ï¼ºÇ°µî ¿Â/½Àµµ ȯ°æÅ×½ºÆ®¸¦ Á¦°øÇÕ´Ï´Ù.
Ç׿ÂÇ×½À±â´Â ÄÁÆ®·ÑºÎ, °èÀåºÎ, ¿ì·¹Åº ÆdzÚ, ¼Ûdz±â, °¡¿­±â, °¡½À±â, ³Ãµ¿±â·Î ÀÌ·ç¾îÁ® ÀÖ½À´Ï´Ù.
¶ÇÇÑ »ç¿ëÀÚ »ç¾ç¿¡ ¸ÂÃç Á¦ÀÛÀÌ °¡´ÉÇÕ´Ï´Ù.

 

 

 


Reliability Chamber - TS Chamber  Custom Made


Specification NTS-2ZL NTS-2ZM NTS-3Z
Exposure Dimension (WxDxH in m) 0.4x0.4x0.4 64L 1.0x1.0x1.0 1.4x0.6x0.6
Test temp. range Low temp. test 30min 30min 30min
Hight temp. test 30min 30min 30min
Type 2zone 2zone 3zone
Low temp. test time -70¡É~-10¡É -70¡É~-10¡É -70¡É~-25¡É
Hight temp. test time 60¡É~220¡É 60¡É~220¡É 25¡É~200¡É
Test restoration time -40¡É~+85¡É(5min) -40¡É~+85¡É(5min) -40¡É~+85¡É(5min)
Cooling Mechanism Air-cooled or Waer-cooled Air-cooled or Waer-cooled Air-cooled or Waer-cooled
Door, Inner Chamber Material Single type door, SUS 304 Single type door, SUS 304 Single type door, SUS 304
Electric other voltage upon request 380V¡¾10%(3,N,PE)AC,50/60Hz 380V¡¾10%(3,N,PE)AC,50/60Hz 380V¡¾10%(3,N,PE)AC,50/60Hz
Temp. variation range ¡¾4¡É ¡¾4¡É ¡¾4¡É
Temp. Uniformity ¡¾7¡É ¡¾7¡É ¡¾4¡É
Physical Dimension(WxDxH in m) 1.17m x 1.97m x 1.9m 1.47m x 1.93m x 1.63m 1.62m x 1.88m x 2.28m




Standard
  • MIL-STD ±Ô°Ý -> MIL-STD-202 : Method 107, Thermal Shock
  • IEC ±Ô°Ý -> IEC 68-2-14 : Basic enviromental testing produce
    Test N : Change of Temperature
  • KS ±Ô°Ý -> KS C 0225 : ȯ°æ½ÃÇè¹æ¹ý -> Àü±â, ÀüÀÚ -> ¿Âµµº¯È­ ½ÃÇè¹æ¹ý

¿­Ãæ°Ý½ÃÇè¿¡ ¿ä±¸µÇ´Â ÆÛÆ÷¸Õ½º¿¡ ´õÇÏ¿© ¿Âµµ º¹±Í ½Ã°£°ú ¿Âµµ»ó½Â, ÇÏ°­ ½Ã°£ÀÇ ´ÜÃà, ¼Òºñ Àü·Â·®ÀÇ Àú°¨, HFC ³Ã¸Å, ¼ÒÀ½ÀÇ Àú°¨, °ø°£ Àý¾àÈ­ ½ÇÇöÇÑ ÃÖ°íÀÇ ¿­Ãæ°Ý ½ÃÇè±âÀÔ´Ï´Ù.

 

 

 


Reliability Chamber - Salt Spray Chamber


Specification NCC-SALT
Exposure Dimension (WxDxH in m) 2.4 x 1.6 x 1.4
Exposure Vol(in Liter) 5300L
Temp.range R.T ~ +60¡É
Temp.accuracy ¡¾1¡É
Temp.Uniformity ¡¾2¡É
Salt
Spray
Method
System Air Pressure System, P.I.D ACTION
Spray Nozzle 25~200
Salt Concentration 5% PH 6.5~7.2
Mist Collection 0~2.5ml/80c§³/hour
Door, Inner Chamber Material Single type door, SUS 304
Electric other voltage upon request 380V¡¾10%(3,N,PE)AC,50/60Hz
Exhaust vent ³»ºÎ ¿°ºÐ, Gas ¹è±â¿ë Vent
Nozzle Spary ºÐ»ç ¾Ð·Â 1.5kg/§³
Physical Dimension(WxDxH in m) 3.00m x 1.70m x 1.60m







¿°¼öºÐ¹«½ÃÇèÀº µµ±Ý ÇǸ·, µµÀå ÇǸ·À̳ª ¾Ë·ç¹Ì´½ ¾ç±Ø »êÈ­ ÇǸ· µîÀÇ Ç¥¸é ó¸®¿Í ½ºÅ×Àθ®½º ¼ÒÀç µîÀÇ Àç·áÀÇ ³»½Ä¼º Æò°¡¸¦ À§ÇÑ ÀåÄ¡ÀÔ´Ï´Ù. ¼Ò±Ý¹°Àº ºÐ¹«Å¾¿¡ ÀÇÇÏ¿© ½ÃÇèÁ¶ ³»¿¡ ±ÕÀÏÇÏ°Ô ºÐ¹«µÇ±â ¶§¹®¿¡, ºÐ»êÀÌ ÀûÀº ½ÃÇèÀ» ÇÒ ¼ö ÀÖ½À´Ï´Ù.

 

 

 


Reliability Chamber - Ammonia Chamber


Specification NCC-AM
Exposure Dimension (WxDxH in m) 2.4 x 1.6 x 1.8
Exposure Vol(in Liter) 5400L
Temp.range R.T ~ +50¡É
Ammonia Exposure 40¡¾3¡É, 667ppm 100% RFH(8hr)
Spray Nozzle Device 2set
1 test
section
Hours 8 including heating up
NH3 - Concentration 6,667 ppm
Temperature 60¡¾3¡É
rel. Humidity Saturation at about 100%
2 test
section
Hours 16 includingcooling
NH3 - Concentration 0ppm
Temperature 18 to 28¡É
rel. Humidity max. 75%
¾Ï¸ð´Ï¾Æ ³ëÃâ 40¡¾3¡É,667ppm 100% RFH(8hrz)
Ambient ³ëÃâ 23¡¾5¡É 0ppm 75% RH(hr)
Cabinet Size 300¡¾10L (750mm x 500mm x 800mm) W x D x H
Ammonia+¼öÁõ±â¹è±â ¾×ü±âÁØ ¹è±â¶û ¾Ï¸ð´Ï¾Æ 4L/500hr ¼öÁõ±â 40L/500hr
Ammonia °¡½ºÅë 10kg







¾Ï¸ð´Ï¾Æ ½ÃÇè Àåºñ´Â ISO 6988:1985(Metallic and other non organic coatings -- Sulfur dioxide test with general condensation of moisture)ÀÇ Test ConditionsÀ» ¸¸Á·ÇÏ´Â Àåºñ·Î Àå½Ã°£ÀÇ ¹Ùº»½ÇÇèÀÌ µÇ¹Ç·Î °ß°íÇÑ ±¸Á¶¸¦ ½ÃÇèÀåºñÀÔ´Ï´Ù.

 

 

 


Reliability Chamber - Explosion Proof Chamber


Specification NEPC
Exposure Dimension (WxDxH in m) 2.5 x 1.8 x 1.8
Exposure Vol(in Liter) 8100L
Test temp.range R.T¡É ~ 200¡É
Temp. & Humid range ¡¾0.2¡É
Temp. & Humid Uniformity ¡¾1¡É
Temp. heat up rate RT ~ 200¡É heating : 4.0k/min
Temp. Pull down rate 200¡É ~ RT Cooling : 1.0k/min
Accessories Cable port : ¡Ë50 x 1ea
Shelves : sts mesh type x 2set
Ä«¸Þ¶ó Åõ½ÃÀå (¹æźÀ¯¸®Àû¿ë)
È­¿°Ä¿Æ° ¼³Ä¡
¼ÒÈ­ÀÚµ¿ ºÐ»ç½Ã½ºÅÛ : HFC-23(ûÁ¤¾àÁ¦)





 

 

 


Àû¿ë°¡´É ±Ô°Ý


UL 1642 Standard for Lithium Batteries
UL 2054 Household and Commercial Batteries
IEC 62133 Safety requirements for portable sealed secondary cells
IEC 62660-2 Secondary lithium-ion cells for the porpulsion of electric road vehicles - Part 2 : Reliability and abuse testing
SAE J2464 Electric and Hybiid Electric Vehicle Rechargeable Energy Storage System (RESS)

ÀÌÂ÷ ÀüÁö´Â ¸ðµç »ê¾÷ºÐ¾ß¿¡ Áß¿ä ÇØÁü¿¡ µû¶ó, ½Å·Ú¼º ¹× ¾ÈÀü¼ºÀÌ ¸Å¿ì Áß¿äÇÕ´Ï´Ù.
´ºÅÇÀÇ ¹æÆø è¹ö´Â °¢ ½ÃÇè±Ô°Ý¿¡ ¸¸Á·ÇÏ¸ç ¹èÅ͸® ½ÃÇè¿¡ µû¸¥ ´©Ãâ ¹× Æø¹ß¿¡ ¾ÈÀüÇÔ.